{"product_id":"elkhart-00008101-nitro-hd-8100hd-water-cannon-monitor","title":"Elkhart 00008101 Nitro HD 8100HD Water Cannon Monitor, 750 GPM","description":"\u003cp\u003eThe \u003cstrong\u003eElkhart 00008101 Nitro HD 8100HD\u003c\/strong\u003e is a severe-duty electric water cannon monitor for mining, construction and mobile water-delivery applications. It has a 2-1\/2-inch FNPT inlet, 2-1\/2-inch MNHT discharge and a rated maximum flow of 750 GPM.\u003c\/p\u003e\u003cp\u003eThis listing is for the \u003cstrong\u003emonitor only\u003c\/strong\u003e. No nozzle, joystick, control module or harnesses are included. Match the complete part number and confirm the required Nitro HD system components before ordering.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSevere-duty design\u003c\/th\u003e\n\u003ctd\u003eDesigned for demanding mining and construction duty cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow-efficient waterway\u003c\/th\u003e\n\u003ctd\u003eFully vaned cast-aluminum waterway helps reduce turbulence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectric positioning\u003c\/th\u003e\n\u003ctd\u003ePermanent-magnet DC gearmotors control horizontal and vertical travel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManual override\u003c\/th\u003e\n\u003ctd\u003eAllows manual positioning when required for service or setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnvironmental protection\u003c\/th\u003e\n\u003ctd\u003eMonitor motors are sealed to NEMA 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eElkhart Brass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer part number\u003c\/th\u003e\n\u003ctd\u003e00008101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eNitro HD 8100HD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum flow\u003c\/th\u003e\n\u003ctd\u003e750 GPM (2,839 LPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e250 PSI (17.2 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet\u003c\/th\u003e\n\u003ctd\u003e2-1\/2-inch female NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDischarge\u003c\/th\u003e\n\u003ctd\u003e2-1\/2-inch male NHT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMonitor weight\u003c\/th\u003e\n\u003ctd\u003e17 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eNitro HD System Compatibility\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNozzle\u003c\/th\u003e\n\u003ctd\u003eUse a compatible 2-1\/2-inch NHT monitor nozzle; the 7000-EHD is the manufacturer-documented electric nozzle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl module\u003c\/th\u003e\n\u003ctd\u003eNitro HD module 81824001 is required for the documented electric-control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eJoystick\u003c\/th\u003e\n\u003ctd\u003eNitro HD joystick 41067000 provides monitor and nozzle control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHarnessing\u003c\/th\u003e\n\u003ctd\u003eUse the correct keyed Nitro HD monitor, module and joystick harnesses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eScope of supply\u003c\/th\u003e\n\u003ctd\u003eMonitor only; nozzle, controls and harnesses are sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eBefore Ordering and Installation\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting clearance\u003c\/th\u003e\n\u003ctd\u003eConfirm full horizontal and vertical travel will clear all nearby equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWater connection\u003c\/th\u003e\n\u003ctd\u003eInstall on a compatible 2-1\/2-inch male NPT connection using the manufacturer-specified sealing method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical system\u003c\/th\u003e\n\u003ctd\u003eMatch the complete Nitro HD control system and follow the current wiring instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHydraulic limits\u003c\/th\u003e\n\u003ctd\u003eDo not exceed the rated flow or pressure; open water valves slowly to reduce water-hammer risk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCommissioning\u003c\/th\u003e\n\u003ctd\u003eVerify secure mounting, correct travel limits, unobstructed movement and leak-free operation before service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Elkhart Brass","offers":[{"title":"Default Title","offer_id":47805478273313,"sku":"0011387","price":5950.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0687\/9245\/1361\/products\/nitro-hd-monitor-only-2-12-fnpt-inlet-x-2-12-mnht-discharge-8100hd-no-nozzle-controls-or-harnesses-elkhart-00008101-915770.jpg?v=1707274830","url":"https:\/\/watertrucks.com\/en-ca\/products\/elkhart-00008101-nitro-hd-8100hd-water-cannon-monitor","provider":"UnitedBuilt Equipment","version":"1.0","type":"link"}