{"product_id":"wika-213-53-glycerin-filled-pressure-gauge-200-psi-2-1-2-dial-1-4-npt-lower-mount-9767088","title":"WIKA 213.53 Glycerin Filled Pressure Gauge, 200 PSI, 2-1\/2\" Dial, 1\/4\" NPT Lower Mount – 9767088","description":"\u003cp\u003eThe \u003cstrong\u003eWIKA 213.53 glycerin filled pressure gauge, part number 9767088\u003c\/strong\u003e, provides a local pressure reading on a \u003cstrong\u003e0–200 PSI scale\u003c\/strong\u003e. This configuration combines a 2-1\/2-inch dial with a \u003cstrong\u003e1\/4-inch NPT lower connection\u003c\/strong\u003e. Match the connection location as well as the thread size when replacing an existing gauge.\u003c\/p\u003e\u003cp\u003eThe glycerin-filled stainless steel case helps damp movement caused by vibration and changing pressure. Copper-alloy wetted parts make fluid compatibility an important selection check: use this model with gases or liquids that do not attack copper alloys and are not highly viscous or prone to crystallizing.\u003c\/p\u003e\u003ch2\u003eA steadier reading in vibrating equipment\u003c\/h2\u003e\u003cp\u003eCase filling damps the pressure element and movement, helping you read the dial where vibration or pressure cycling makes an unfilled gauge harder to follow. The mechanical Bourdon-tube design provides a pressure indication without an electrical supply.\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBenefit\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGlycerin-filled case\u003c\/th\u003e\n\u003ctd\u003eDamps movement in applications with vibration and dynamic pressure loads.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2-1\/2-inch dial\u003c\/th\u003e\n\u003ctd\u003eProvides a local visual pressure indication in a compact gauge size.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLower connection\u003c\/th\u003e\n\u003ctd\u003eMatches installations that require the process connection below the dial.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStainless steel case\u003c\/th\u003e\n\u003ctd\u003eProtects the gauge mechanism in an IP65 enclosure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer and model\u003c\/th\u003e\n\u003ctd\u003eWIKA 213.53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer part number\u003c\/th\u003e\n\u003ctd\u003e\u003cstrong\u003e9767088\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIndicated range\u003c\/th\u003e\n\u003ctd\u003e0–200 PSI; single PSI scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal dial size\u003c\/th\u003e\n\u003ctd\u003e2-1\/2 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess connection\u003c\/th\u003e\n\u003ctd\u003e1\/4-inch NPT, lower mount (LM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCase fill\u003c\/th\u003e\n\u003ctd\u003eGlycerin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConstruction\u003c\/th\u003e\n\u003ctd\u003eStainless steel case; copper-alloy wetted parts; clear plastic window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003eASME B40.100 Grade A, ±2\/1\/2% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e−4 to 140°F (−20 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum medium temperature\u003c\/th\u003e\n\u003ctd\u003e140°F (60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eMatch the gauge to the installation\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eApplication or component\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSelection guidance\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWater and hydraulic pressure monitoring\u003c\/th\u003e\n\u003ctd\u003eConfirm the actual fluid is compatible with copper-alloy wetted parts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReplacement mounting position\u003c\/th\u003e\n\u003ctd\u003eUse lower mount; a center-back gauge connects behind the case, not below it.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure connection\u003c\/th\u003e\n\u003ctd\u003eMatch the 1\/4-inch NPT port and provide any adapters or isolation components required by your installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVibration and pressure cycling\u003c\/th\u003e\n\u003ctd\u003eCheck the system pressure peaks and pulsation conditions as well as the normal reading.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore ordering\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eA 200 PSI dial does not mean 200 PSI continuous service.\u003c\/strong\u003e Select the range for the actual operating pattern: steady pressure is limited to three-quarters of full scale, fluctuating pressure to two-thirds, and full-scale pressure to short-duration exposure.\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eCheck\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking pressure\u003c\/th\u003e\n\u003ctd\u003eMaximum steady pressure: 150 PSI. For fluctuating service, stay at or below two-thirds of the 200 PSI full scale.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature\u003c\/th\u003e\n\u003ctd\u003eKeep the process medium at or below 140°F and ambient temperature within −4 to 140°F.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFluid compatibility\u003c\/th\u003e\n\u003ctd\u003eDo not use media that attack copper alloys, crystallize, or are highly viscous.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFit and installation\u003c\/th\u003e\n\u003ctd\u003eConfirm connection location, thread, dial clearance and any required mounting hardware. Have qualified personnel install it with the system depressurized; tighten at the wrench flats, not the case.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSafety function\u003c\/th\u003e\n\u003ctd\u003eFor pressure indication only, not safety or emergency shutdown devices. Do not use in potentially explosive atmospheres.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eCalifornia Proposition 65 warning:\u003c\/strong\u003e Exposure to lead and nickel from this product may cause cancer, birth defects or other reproductive harm. More information is available at \u003ca href=\"https:\/\/www.P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eNeed help selecting the correct pressure gauge? Contact UnitedBuilt through online chat, email \u003ca href=\"mailto:parts@unitedbuilt.com\"\u003e\u003cstrong\u003eparts@unitedbuilt.com\u003c\/strong\u003e\u003c\/a\u003e, or call \u003ca href=\"tel:+16022537750\"\u003e\u003cstrong\u003e602-253-7750\u003c\/strong\u003e\u003c\/a\u003e with your connection location, operating pressure and fluid type.\u003c\/p\u003e","brand":"WIKA","offers":[{"title":"Default Title","offer_id":54026402824481,"sku":"0012855","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0687\/9245\/1361\/files\/213.53_en_co_rs_w700_h700_image_aca1287d-80b6-4f0d-ab09-c01108d6706e.jpg?v=1792787601","url":"https:\/\/watertrucks.com\/fr-ca\/products\/wika-213-53-glycerin-filled-pressure-gauge-200-psi-2-1-2-dial-1-4-npt-lower-mount-9767088","provider":"UnitedBuilt Equipment","version":"1.0","type":"link"}