Carling 6FC54-73 Momentary SPDT Toggle Switch — UnitedBuilt Equipment Skip to content
Quality Water Truck Systems, Tanks & Parts Since 1947
Quality Water Truck Systems, Tanks & Parts Since 1947

Toggle Switch, Momentary On-Off-On, SPDT, Carling 6FC54-73

SKU 0009823
Availability:
5 in stock | Available on backorder
Original price $0.00 - Original price $0.00
Original price $0.00
$13.00
$13.00 - $13.00
Current price $13.00

Product Images

Images are for representation only and may differ from the actual product.

Questions about this product?

The Carling 6FC54-73 F-Series toggle switch combines momentary-on / off / momentary-on operation with screw terminals and an unsealed bat-style lever. Its SPDT circuit selects either outer contact while the lever is held, with an off position at the center.

This configuration uses a 0.687-inch toggle and a 0.465-inch threaded bushing. It is not the sealed actuator option or a quick-connect tab version; check those details before treating another F-Series switch as a replacement.

Clear action and terminal selection

Feature Benefit
Momentary outer positions Supports commands that should not stay latched on.
Screw terminals Provides screw-secured wiring connections.
Center-off circuit Separates the two momentary selections with an off position.

Technical specifications

Specification Details
Manufacturer part number 6FC54-73
Series F-Series
Circuit and action SPDT; Momentary On / Off / Momentary On
AC ratings 15 A at 125 VAC; 10 A at 250 VAC
Termination Screw terminals; #6-32 NC-2 terminal-screw thread
Actuator Unsealed bat handle; 0.687-inch length
Mounting bushing 15/32-32 UNS-2A thread; 0.465-inch length
Mounting hole 0.500-inch diameter; confirm anti-rotation arrangement
Operating temperature 0 to 150 degrees F (-17.8 to 65.6 degrees C)

Before ordering

Check What to confirm
AC versus DC The listed amperage ratings are AC ratings. Confirm the exact DC load rating with the manufacturer before use in a vehicle DC circuit.
Mounting thread The #6-32 thread belongs to the terminal screw, not the mounting bushing.
Environment The -73 actuator is unsealed; use an installation suited to that construction.
Fit and wiring Confirm panel thickness, rear clearance, terminal arrangement and momentary switching action.
Installation Disconnect electrical power before wiring or replacing the switch.

Need help confirming the switch configuration? Contact UnitedBuilt through online chat, email parts@unitedbuilt.com, or call 602-253-7750 with your system voltage, load type and mounting details.