Questions about this product?

The Elkhart Brass 81960001 travel limit sensor kit replaces a position sensor on compatible Sidewinder water cannon monitors. It supports the travel-limit function that stops monitor movement at the end of its operating range.

Use this kit for vertical sensor replacement on the 8494-01 Sidewinder Electric or 8494-RF Sidewinder RF, or for horizontal sensor replacement on the 8494-01 only. Each kit contains one sensor; order a separate kit for each sensor being replaced.

Service the affected sensor

Feature Practical benefit
Single-sensor replacement Replace the affected travel-limit sensor without purchasing a complete monitor.
Installation instructions included Provides the mounting and function-check procedure for the applicable sensor position.

Included components

Component Quantity / part number
Position sensor 1 — 67570000
Installation instructions 1 — 98655000

Mounting screws, washers, and the cable clamp are not included. Retain the existing hardware for reuse as directed in the installation instructions.

Compatible sensor positions

Monitor Sensor position
8494-01 Sidewinder Electric Vertical or horizontal
8494-RF Sidewinder RF Vertical

Before ordering

Check What to confirm
Monitor and sensor Match the model, sensor position, existing connector, and mounting arrangement.
Older configurations Confirm the replacement path for older sensors or modified wiring before ordering.
Installation Disconnect power. Follow instruction 98655000 for sensor orientation, hardware placement, and threadlocker.
Fastener torque Tighten sensor screws gradually and alternately to 6.0 in-lb.
Return to service Keep the travel area clear and verify that movement stops at both limits through repeated cycles.